Print this page

Sunna Solar Power

Sunna Solar Power imported many grid interactive inverters, however Sunna Solar Power are no longer in business.

Since they are no longer operating there is no support of their products.? However we can repair some of the faults in the 1500TL, 2000TL, 3000Tl, 4200TL, and 5000TL grid interactive inverters.?

Here is a list of the Sunna Solar Power inverter fault codes.

Er00 DC_BUS pre-Charge fail, the DC Bus cannot reach and maintain anticipated charging voltage.
Er03 INVERTER voltage abnormal The Inverter Output voltage is abnormal.
Er07 DC_BUS over-voltage The DC BUS inside is lower or high than expected.
Er08 DC_BUS under-voltage.
Er17 EEPROM ERROR on the control board EEPROM Data is wrong.
Er19 DC_BUS discharge fail Capacitors of the DC Bus can?t be discharged down.
Er22 Output Relay fail The Inverter Output Relay is abnormal.
Er24 Output Current sense fail The Inverter Output Current fails to detect.
Er25 BOOSTER_A over-current Over-current on the DC side.
Er26 BOOSTER_B over-current network is larger than specified.
Er30 Rating setting of Driver board does not match EEROM of control board.
Er06 EPO Inverter enters into EPO mode (Emerge Power Off).
Er09 Inverter Output over-current Over-current on the AC side.
Er11 Inverter over-load Overload on the AC side.
Er13 Inverter short-circuit Short-circuit on the AC side.
Er14 Inverter PLL fail The phase of Inverter can?t synchronise with the utility.
Er29 Inverter output DC current over spec.
Er10 Inverter Over temperature The internal temperature is too high.
Er18 Heat Sink Over temperature The Heat Sink temperature is too high.

AL00 Grid voltage to high
AL01 Grid voltage to low
AL02 Grid frequency to high>br> AL03 Grid frequency to low
AL04 Booster_A input over voltage
AL05 Booster_A input under voltage
AL06 Booster_B input over voltage
AL07 Booster_B input under voltage
AL08 Anti Islanding
AL09 Inverter voltage is unbalanced
AL10 GFDI Ground fault
AL11 Isolation fault
AL13 Grid phase is bad
AL14 Gird waveform is bad

Contact us if you have a faulty Sunna Solar Power inverter that needs repair.


Previous page: Inspire Solar